24. SERVICE PROCEDURE 24. SERVICE PROCEDURE 7. Bleeding air from travel motor circuit If the piping of the travel motor circuit has been removed and installed again, run the engine at low idling and bleed the air as follows. 1. Start the engine and run at low idling. 2. Remove travel motor cover 1 , then loosen air bleed plug 2 one turn. NOTICE Do not loosen plug 2 more than one turn. 3. Operate the travel lever lightly and drive the machine 4 – 5 times in succession forward and in reverse. 4. When no more milky white oil comes out from air bleed plug 2 , tighten air bleed plug 2 . 5. Install the travel motor cover. 24.10.3 CLEAN ENGINE BREATHER 1.
Remove 2 breather mounting bolts, then remove breather 1 . 2. Rinse the breather in diesel oil or flushing oil, dry with com- pressed air, then install again. Before removing the breather 1 , clean all the dirt from around it. Replace the breather O-ring with a new part, and coat it with engine oil before installing. 24.10.4 CLEAN, CHECK TURBOCHARGER Contact your Komatsu distributor for cleaning or inspection. 24.10.5 CHECK ALTERNATOR, STARTING MOTOR The brushes may be worn, or the bearing may have run out of grease, so contact your Komatsu distributor for inspection or repair. If the engine is started frequently, carry out inspection every 1000 hours.
24.10.6 CHECK ENGINE VALVE CLEARANCE, ADJUST As special tool is required for removing and adjusting the parts, request Komatsu distributor for service. 3-82