Komatsu — 12.1 CHECK BEFORE STARTING ENGINE

12. OPERATION 12. OPERATION CHECK AIR CLEANER FOR CLOGGING 1. Confirm that the air cleaner clogging monitor does not flash. 2. If it flashes, immediately clean or replace the element. For details of method of cleaning the element, see “24.3.1 CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT”. CHECK ELECTRIC WIRINGS ¤ WARNING If fuses are frequently blown or if there are traces of short circuit on the electrical wiring, locate the cause and carry out repair. Accumulation of flammable material (dead leaves, twigs, grass, etc.) around the battery may cause fire, so always check and remove such material. Keep the top surface of the battery clean and check the breather hole in the battery cap.

If it is clogged with dirt or dust, wash the battery cap to clean the breather hole. Check for damage and wrong capacity of the fuse and any sign of disconnection or short circuit in the electric wiring. Check also for loose terminals and tighten any loose parts. Check the wiring of the “battery”, “starting motor” and “alter- nator” carefully in particular. When carrying out walk-around checks or checks before starting, always check if there is any accumulation of flammable material around the battery, and remove such flammable material. Please contact your Komatsu distributor for investigation and correction of the cause. CHECK FUNCTION OF HORN 1.

Turn the starting switch to the ON position. 2. Press the horn switch and check that the horn sounds immedi- ately. Note that if the air tank is empty or the water drain valve in the air tank is at the OPEN position, the horn will not sound. Check that the water drain valve is at the CLOSE position, start the engine and wait for 1 or 2 minutes, then press the horn switch again to check if it sounds. If the horn still does not sound, please contact your Komatsu distributor for repairs. 2-37