Komatsu — 12.1 CHECK BEFORE STARTING ENGINE

12. OPERATION 12. OPERATION DRAIN WATER AND SEDIMENT FROM FUEL TANK 1. Prepare a container to catch the fuel that is drained out. 2. Take drain hose 2 out through the hole in cover 3 . 3. Open drain valve 1 at the bottom of the aftercooler and drain the water and sediment gathered at the bottom of the tank together with fuel. When doing this, be careful not to get fuel on yourself. 4. When clean fuel comes out, close drain valve 1 . NOTICE Do not use trichlene to wash the inside of the tank. CHECK CENTRAL MONITOR To prevent any failure to give a warning caused by a blown lamp bulb on the central monitor or defective operation of the buzzer, carry out the following checks. 1.

Before starting the engine, turn the starting switch to the ON position and check that all monitors and gauges light up for approx. 3 seconds and that the alarm buzzer sounds for approx. 1 second. If any lamp does not light up during this time or the buzzer does not sound, there is probably a blow bulb or disconnection, so please contact your Komatsu distributor for inspection. 2-38