Maintenance—Periodic Maintenance Hydraulic Breaker and Crusher Attachments IMPORTANT: Avoid mixing different brands or types of oils. Oil manufacturers engineer their oils to meet certain specifications and performance requirements. Mixing different oil types can degrade lubricant and machine performance. This excavator is factory filled with Super EX 46HN extended life zinc-free hydraulic oil. Avoid servicing this excavator with products that do not meet this specification. If oils have been mixed or if alternate service oils are desired, the complete hydraulic system needs to be totally flushed by an authorized dealer.
Hydraulic breaker or crusher operation subjects the machine’s hydraulic system to possible contamination and accelerated deterioration. The hydraulic return filter and hydraulic oil must be replaced frequently to prevent damage to hydraulic pumps and other hydraulic components. Change the hydraulic return filter and oil at the intervals recommended below based on the amount of machine operating time the attachment is used. NOTE: John Deere recommends the addition of the hydraulic filter restriction indicator kit with the attachment.
Percentage of Operating Time Hydraulic Return Filter Hydraulic Oil Change Ordinary Bucket Used Change Interval (hours) Interval (hours) 100 500 4000 Breaker or Crusher Used Change Interval (hours) Interval (hours) 100 100 500 DW90712,000005F –19–03JUL07–1/1 3-2-4 010609 PN=121