Maintenance—As Required Check Air Cleaner Element 450DLC and 650DLC 1. Unscrew wing nut (1), and remove outer cover. 2. Unscrew wing nut (2) to remove primary element. TX1001778A –UN–21DEC05 3. Pull primary element (3) straight back to remove. 4. Tap primary element with the palm of your hand, NOT ON A HARD SURFACE. CAUTION: Prevent possible injury from flying chips if compressed air is more than 210 kPa (2.1 bar) (30 psi). Reduce compressed air to less than 210 kPa (2.1 bar) (30 psi) when using for cleaning purposes. Clear area of bystanders, guard against flying chips, and wear personal protection equipment including eye protection. TX1001781A –UN–03JAN06 5.
If this does not remove dust, use compressed air under 210 kPa (2.1 bar) (30 psi). Specification Compressed Air—Pressure Under 210 kPa (2.1 bar) (30 psi) ................... 6. Direct air up and down from inside to outside. Be careful not to make a break in the element. 1—Outer Cover Wing Nut 2—Primary Element Wing Nut 3—Primary Element 7. Install primary element (3), and securely screw on wing nut (2). 8. Install outer cover, and securely screw on wing nut (1). DW90712,000000F –19–31OCT06–1/1 3-3-2 010609 PN=129