Maintenance—Every 500 Hours Bleed Air From Hydraulic System—650DLC and 850DLC IMPORTANT: If the hydraulic pump is not filled with oil, it will be damaged when the engine is started. Avoid mixing different brands or types of oils. Oil manufacturers engineer their oils to meet certain specifications and performance requirements. Mixing different oil types can degrade lubricant and machine performance. This excavator is factory filled with Super EX 46HN extended life zinc-free hydraulic oil. Avoid servicing this excavator with products that do not meet this specification.
If oils have been mixed or if alternate service oils are desired, the complete hydraulic system needs to be totally flushed by an authorized dealer. TX1011082 –UN–10AUG06 1. Loosen plugs (6 and 7). 850DLC Shown 2. Fill the pumps with oil through plug ports. 3. Tighten the plugs. 4. Start the engine and run at slow idle. Put a Not Operate” tag on the pilot control shutoff lever. Make sure the pilot control shutoff lever is in the LOCK position. 5. Slowly loosen plugs (6 and 7) to release trapped air. Tighten the plug when air stops and oil flows. 6. Purge air from the hydraulic system by running the engine at slow idle and operating all control levers slowly and smoothly for 15 minutes.
TX1011083 –UN–10AUG06 7. Position the machine with the arm cylinder fully retracted and the bucket cylinder fully extended. 8. Lower the bucket to the ground. 6—Plug (2 used) 7—Plug Continued on next page DW90712,0000020 –19–03JUL07–1/2 3-7-8 010609 PN=163