John Deere 450DLC, 650DLC, and 850DLC Excavators — Cooling System Fill and Deaeration Procedure

Maintenance—Every 2000 Hours Cooling System Fill and Deaeration Procedure Specification 450DLC—Refill Capacity 48.0 L ........................................................... 12.7 gal 650DLC—Refill Capacity 56.0 L ........................................................... 14.8 gal 850DLC—Refill Capacity 81.4 L ........................................................... 21.5 gal normal operation. Only during warm-up and cool down cycles will the system deaerate. 1. Start engine. Run engine until coolant reaches a warm temperature. IMPORTANT: Use only permanent-type low silicate ethylene glycol base antifreeze in coolant solution. Other types of antifreeze may damage cylinder seals. 2.

Stop engine. Allow coolant to cool. 3. Check coolant level at recovery tank. 4. Repeat Steps until recovery tank coolant level is repeatedly at the same level (stabilized). FREEZING TEMPERATURES: Fill with permanent-type, low silicate, ethylene glycol antifreeze (without stop-leak additive) and clean, soft water. NOTE: The level of the coolant in the cooling system MUST BE repeatedly checked after all drain and refill procedures to insure that all air is out of the system which allows the coolant level to stabilize. Check coolant level only when the engine is cold. Fill Fill radiator to the bottom of the radiator fill neck. Fill the recovery tank to FULL mark. 5.

If necessary, fill recovery tank to FULL mark. Deaeration The cooling system requires several warm-up and cool down cycles to deaerate. It will NOT deaerate during DW90712,00000EB –19–28MAR06–1/1 3-9-5 010609 PN=179