Maintenance—Every 4000 Hours Change Hydraulic Tank Oil, Clean Suction Screen NOTE: Change original factory fill hydraulic oil after first 4000 hours. Change every 4000 hours thereafter if using Super EX 46HN, if using alternative oils see Hydraulic Oil. (Section 3-1.) T6811AJ –UN–18OCT88 IMPORTANT: Prevent damage to hydraulic system components. DO NOT run engine without oil in the tank. Avoid mixing different brands or types of oils. Oil manufacturers engineer their oils to meet certain specifications and performance requirements. Mixing different oil types can degrade lubricant and machine performance.
TX1003486A –UN–08FEB06 This excavator is factory filled with Super EX 46HN extended life zinc-free hydraulic oil. Avoid servicing this excavator with products that do not meet this specification. If oils have been mixed or if alternate service oils are desired, the complete hydraulic system needs to be totally flushed by an authorized dealer. 650DLC Shown 1—Pressure Release Button 1. Park machine on level surface with upperstructure rotated 90 ° for easier access. 2. Position machine with arm cylinder fully retracted and bucket cylinder fully extended. 3. Stop engine. CAUTION: High pressure release of oil from pressurized system can cause serious burns or penetrating injury.
The hydraulic tank is pressurized. Relieve pressure by pushing the pressure release button (1). 4. To relieve pressure, push the pressure release button (1). 5. Remove cap. Continued on next page DW90712,0000023 –19–03JUL07–1/5 3-11-1 010609 PN=180