John Deere 450DLC, 650DLC, and 850DLC Excavators — Replacing Batteries

Miscellaneous—Machine Using Battery Charger CAUTION: Prevent possible injury from exploding battery. Do not charge a battery if the battery is frozen or it may explode. Warm battery to 16 ° C (60 ° F) before charging. Turn off charger before connecting or disconnecting it. TS204 –UN–23AUG88 IMPORTANT: Do not use battery charger as a booster if a battery has a 1.150 specific gravity reading or lower. Disconnect battery ground clamp before you charge batteries in the machine to prevent damage to electrical components. A battery charger may be used as a booster to start engine. Ventilate the area where batteries are being charged.

N36890 –UN–07OCT88 Stop or cut back charging rate if battery case feels hot, or is venting electrolyte. Battery temperature must not exceed 52 ° C (125 ° F). DW90712,0000456 –19–18JAN07–1/1 Replacing Batteries Your machine has two 12-volt batteries with negative (-) ground. Batteries must meet one of the specifications below. If one battery in a 24-volt system has failed but the other is still good, replace the failed battery with one of the same type. For example, replace a failed maintenance-free battery with a new maintenance-free battery. Different types of batteries may have different rates of charge. This difference could overload one of the batteries and cause it to fail.

Specification Battery—Cold Cranking Amps At -18 ° C (0 ° F) 800 ................................................................................ Battery—Minutes Reserve Capacity At 25 Amps 180 ..................................................................... TX,90,DH5153 –19–03JAN07–1/1 4-1-6 010609 PN=188