Track System TM1859 (14JUL04) 01-0130-67 700H Crawler Dozer 071404 PN=117 Welding Procedure IMPORTANT: Before welding on this machine: To avoid electronic component damage, turn the electrical (battery) disconnect switch off. • Turn (S2) electrical (battery) disconnect switch OFF. • Clamp the welding ground clamp as close to the point of welding as possible. • Never attach welding ground clamp to a track pad. • Remove dirt, oil and paint from areas to be welded. • Use 5/32 inch diameter low hydrogen AWS-ASTM E-7018 covered electrode. NOTE: Flux covering on low hydrogen electrodes readily takes on moisture which causes welding problems. Be sure electrodes are dry.
Electrodes stored in open containers should be suspected of containing excessive moisture and may require baking prior to use. Use AC or DC reversed polarity welding current ELECTRODE POSITIVE (+). The suggested amperage is 100—115 amps. CED,TX03399,5965 –19–24MAR00–1/1 01 0130 67