Remove and Install Hydrostatic Motors Removal and Installation 1. Lower all equipment to ground. 2. Stop engine. Operate all hydraulic controls to release pressure in hydraulic system. 3. Turn battery disconnect switch to OFF. NOTE: Reservoir capacity is approximately 65.1 L (17.2 gal). 4. Drain reservoir or remove hydrostatic reservoir check valve and attach vacuum pump to elbow. 03 0300 5. Remove rear access cover or rear mounted optional equipment and hydrostatic motor bottom access plates, if necessary. 16 Continued on next page CED,TX03399,5974 –19–24MAR00–1/4 TM1859 (14JUL04) 03-0300-16 700H Crawler Dozer 071404 PN=160