Hydrostatic System IMPORTANT: Threaded holes in swashplate and pump housing side cover opening must be cleaned of old locking compound prior to reassembly. 61. Clean the threaded holes in the swashplate (A) and pump housing side cover opening (B) using the correct tap. RW25729 –UN–16JUN97 RW25744 –UN–16JUN97 IMPORTANT: Pump housing must be clear of any contamination before assembling pump. 62. Clean inside of pump housing eliminating any excess thread locking compound or other contamination. A—M6 Threaded Holes in Swashplate B—M8 Threaded Holes in Housing 03 0360 17 CED,OUTX547,110 –19–28JUN02–22/22 TM1859 (14JUL04) 03-0360-17 700H Crawler Dozer 071404 PN=207