Hydrostatic System 15. Apply clean hydrostatic oil to valve segment and bearing plate mating surfaces. Install end cap assembly and valve segment. The spindle must engage the bearing in the cylinder block. IMPORTANT: DO NOT allow the pistons or synchronizing shaft rollers to fall out of position. 16. Install correct length screws in corresponding locations. NOTE: The internal spring in the motor shaft should hold the end cap away from the housing a short distance. 03 0360 17. Tighten the screws by hand in the sequence shown (1—8) while rotating the motor shaft to ensure proper positioning of the synchronizing shaft rollers. 56 IMPORTANT: DO NOT force the end cap into position on the housing.
T8506AP –UN–10JUL95 18. Tighten screws using sequence shown to approximately 1/2 final torque value. Repeat sequence and tighten to final torque. Specification Motor End Cap-to-Housing Screw——Torque 135 (100 lb-ft) ........................................................ 19. Rotate shaft 360 ° to check final assembly. T8506AQ –UN–10JUL95 Continued on next page CED,TX03399,5995 –19–14JUL04–6/9 TM1859 (14JUL04) 03-0360-56 700H Crawler Dozer 071404 PN=246