John Deere 700H Crawler Dozer — Refrigerant Recovery, Recycling and Charging Station Installation Procedure

Heating and Air Conditioning TM1859 (14JUL04) 18-1830-15 700H Crawler Dozer 071404 PN=459 R134a Refrigerant Recovery, Recycling and Charging Station Installation Procedure ESSENTIAL TOOLS JT02045R134a Refrigerant Recovery/Recycling and Charging Station a aJT02046 and JT02050 recovery and charging stations can be substituted for the JT02045 station. CAUTION: Do not remove high pressure relief valve (A). Air conditioning system will discharge rapidly causing possible injury. IMPORTANT: Use correct refrigerant recovery, recycling and charging stations. DO NOT mix refrigerant, hoses, fittings, components or refrigerant oils. 1.

Close both high and low pressure valves on refrigerant recovery, recycling and charging station (H). –19–22FEB95 2. Remove cap from low pressure test port (G). 3. Connect low pressure blue hose (D) from refrigerant T8422AC recovery, recycling and charging station (H) to low pressure test port (G) on compressor. A—High Pressure Relief Valve 4. Connect high pressure red hose (C) to high pressure B—High Pressure Test Port quick disconnect (B). C—Red Hose D—Blue Hose 5. Follow the manufacturer’s instructions when using the E—High Pressure Hose refrigerant recovery, recycling and charging station.

F—Low Pressure Hose G—Low Pressure Test Port H—Refrigerant Recovery/Recycling and Charging Station CED,OUTX547,176 –19–21OCT98–1/1 18 1830 15