John Deere 700H Crawler Dozer — Recover System

Recover R134a System Heating and Air Conditioning ESSENTIAL TOOLS JT02045R134a Refrigerant Recovery/Recycling and Charging Station a a JT02046 and JT02050 recovery and charging stations can be substituted for the JT02045 station. 18 1830 16 CAUTION: Do not remove high pressure relief valve (A). Air conditioning system will discharge rapidly causing possible injury. IMPORTANT: Use correct refrigerant recovery, recycling and charging stations. DO NOT mix refrigerant, hoses, fittings, components or refrigerant oils. NOTE: Run the air conditioning system for three minutes to help in the recovery process. Turn air conditioning system off before proceeding with recovery steps.

T8422AC –19–22FEB95 1. Connect refrigerant recovery, recycling and charging station. (See installation procedure in this group.) 2. Follow the manufacturer’s instructions when using the refrigerant recovery, recycling and charging station. A—High Pressure Relief Valve B—High Pressure Test Port C—Red Hose D—Blue Hose E—High Pressure Hose F—Low Pressure Hose G—Low Pressure Test Port H—Refrigerant Recovery/Recycling and Charging Station CED,OUTX547,177 –19–21OCT98–1/1 TM1859 (14JUL04) 18-1830-16 700H Crawler Dozer 071404 PN=460