Heating and Air Conditioning 8. Attach a return hose and aerator nozzle to outlet end of receiver/dryer inlet hose using JT03197 Adapter. Put nozzle in container to collect flushing solvent. 15. Force flushing solvent through evaporator inlet with compressed air. 16. Purge system until dry. (See Purge Air Conditioner System in this group.) 9. Fill flusher tank with 4 L (1 gal) of solvent and fasten all connections. 17. Install evaporator. 18 1830 Specification Flusher Tank—Capacity 4 L (1 gal) .................................................... 18. Go to Step 22. 24 NOTE: Air pressure must be at least 620 kPa (6.2 bar) (90 psi) for flushing and purging. 19.
To Flush Evaporator Through Expansion Valve: Connect flusher outlet hose to connection of receiver/dryer outlet hose using JT03188 Adapter. 10. Connect a supply line of moisture-free compressed air or dry nitrogen to flusher air valve. Adjust regulator to specification. 20. Attach a hose and aerator nozzle to compressor inlet line using JT02101 Adapter. Put nozzle in a container to collect solvent. Specification Regulated Air—Pressure 620 kPa (6.2 bar) (90 psi) Minimum ........................... 11. Open air valve to force flushing solvent into condenser circuit. Flusher tank is empty when hose pulsing stops.
Additional flushing cycles are required if system is heavily contaminated with burned oil or metal particles. 21. Repeat Steps 8, 9 and 10 to flush evaporator. NOTE: Purging the evaporator circuit takes 12—15 minutes to thoroughly remove solvent. 22. Disconnect hose from aeration nozzle to check circuit for solvent. Hold hose close to a piece of cardboard. Continue purging until cardboard is dry. NOTE: Purging the condenser circuit takes 10—12 minutes to thoroughly remove solvent. 23. Install a new receiver-dryer compatible with R134a refrigerant. (See Remove and Install Receiver-Dryer in this group.) Tighten connections and mounting bracket.
Specification Condenser Purging—Time 10—12 Minutes ......................................... 12. Disconnect hose from aeration nozzle to check circuit for solvent. Hold hose close to a piece of cardboard; continue purging until cardboard is dry. 24. Add required oil. (See R134a Component Oil Charge in this group.) 13. Go to Step 13 to flush evaporator. Go to Step 22 if evaporator does not require flushing. 25. Install compressor, and connect refrigerant lines to manifold. 14. To Flush Evaporator: 26. Connect clutch coil wire. Install drive belt. If system is contaminated with burned refrigerant oil or debris, remove and bench flush evaporator.
Go to Step 18 to flush evaporator through expansion valve, if oil appears normal. Remove evaporator. (See Remove and Install Evaporator or Heater Core in this group.) 27. Purge system. (See procedure in this group.) TM1859 (14JUL04) 18-1830-24 700H Crawler Dozer CED,TX03399,2293 –19–16APR99–2/2 071404 PN=468