John Deere 700H Crawler Dozer — Flush System

Heating and Air Conditioning TM1859 (14JUL04) 18-1830-23 700H Crawler Dozer 071404 PN=467 Flush Air Conditioner System SPECIFICATIONS Specification Compressor Flushing Solvent— Compressor Flushing Solvent 240 mL (8 fl oz) In Suction Port Quantity............................................. 240 mL (8 fl oz) In Suction Port Quantity Quantity................................................. 120 mL (4 fl oz) In Discharge Compressor Flushing Solvent 120 mL (4 fl oz) In Discharge Port Quantity Port Flusher Tank Capacity 4 L (1 gal) Regulated Air Pressure 620 kPa (6.2 bar) (90 psi) Minimum b. Turn compressor end for end and roll it side to Condenser Purging Time 10—12 Minutes side.

Evaporator Purging Time 12—15 Minutes c. Remove both plugs from manifold ports and drain solvent from compressor. ESSENTIAL TOOLS JT02075 Air Conditioning Flusher d. Connect battery power to compressor clutch coil. JT02098 Fitting Kit Rotate pulley at least five revolutions to move JT02099 and JT02100 with JT03194 Cap solvent out of cylinders. JT02102 Adapter e. Invert compressor, roll end for end, and side to SERVICE EQUIPMENT AND TOOLS side. Drain thoroughly. JT03188 Adapter f. Let compressor sit inverted for three to five JT02101 Adapter minutes. Add flushing solvent to system with JT02075 Air g. Repeat previous two steps at least three times. Conditioning Flusher and JT02098 Fitting Kit.

5. Remove and discard receiver-dryer. NOTE: Flushing can be performed on vehicle. 6. Divide system into two circuits: 1. Recover refrigerant. (See Recover R134a System procedure in this group.) a. Condenser, including inlet and outlet hoses. (Steps 6—12) 2. Remove compressor. (See Remove and Install Compressor in this group.) b. Evaporator, including inlet and outlet hoses. (Steps 13—26) 3. Drain and measure oil drained from manifold ports. (See R134a Compressor Oil Removal in this IMPORTANT: DO NOT attempt to flush through group.) compressor or receiver-dryer. Flushing through expansion valve is 4. Clean compressor as follows: acceptable if refrigerant oil has normal odor and appearance. a.

Pour specified amount of flushing solvent into suction port and specified amount of flushing 7. To Flush/Purge Condenser: solvent into discharge port. Plug both ports in compressor manifold, using caps. Connect flusher outlet hose to inlet end of compressor discharge line using JT02102 Adapter. Continued on next page CED,TX03399,2293 –19–16APR99–1/2 18 1830 23 SPECIFICATIONS Compressor Flushing Solvent Quantity 240 mL (8 fl oz) In Suction Port Compressor Flushing Solvent Quantity 120 mL (4 fl oz) In Discharge Port Flusher Tank Capacity 4 L (1 gal) Regulated Air Pressure 620 kPa (6.2 bar) (90 psi) Minimum Condenser Purging Time 10—12 Minutes Evaporator Purging Time 12—15 Minutes