Komatsu — WHEN REQUIRED

. MAINTENANCE SERVICE PROCEDURE CLEAN FINS WITH COMPRESSED AIR WARNING CLEANING WITH REAR GRILL OPEN when cleaning. 4 - 31 Before opening the fan guard, stop the eng ine, and hang a warning ta g on the work equipment control 1. Open rear grill (1 2. Remove bolts (3) and open fan gu 3. Us e c ompresse d air to blow out fins (4). It is als any mud, d irt, or leaves clogging radiator o possible to use steam or eam water in place of compressed air. NOTIC If the s E team jet nozzle is brought too close to the radiator fins, it may damag e the fins, so kee p the nozzle a suitable distance away from the fins Work under the f ollowing rough co nditions. kg/cm2) 2 mm Jet pressure:

Max 9.8 MPa (100 Nozzle diamet er: Max diameter Distance betw een nozzle and ra diator fins: M in 100 mm 4. Check the rubber hose. Replace w ith a new one if the h ose is f ound to have cracks or to be hardened by aging Also, check hose clamps for loose 5. After cleaning, cl ose fan guard (2) and install bo lts (3).