UENR4490-01 103 Air Inlet and Exhaust System Illustration 96 g03370974 Typical example Note: This test should run for 5 minutes. If the test only runs for 1 minute, repeat the test a further four times. 8. After the test has completed, check the measuring container to inspect the amount of DEF in the container. Dispose of the collected DEF as per local regulations and mandates. Specification for DEF sprayed during dosing test . . . . . . . . . . . . . . . . . . . . . . . . . 105 mL to 130 mL 9. Reinstall the DEF injector assembly. Refer to Disassembly and Assembly, “DEF Injector and Mounting - Remove and Install” for the correct procedure. Illustration 97 g03370954 Typical example 7.
Click Start to proceed with the test. Note: With the DEF injector dosing, inspect the spray pattern. The injector spray pattern should be finely atomized and conical.