UENR4490-01 125 Electrical System Alternator output should be 28 ± 1 V on a 24 V system and 14 ± 0.5 V on a 12 V system. No adjustment can be made in order to change the rate of charge on the alternator regulators. If the rate of charge is not correct, a replacement of the regulator is necessary. For individual alternator output, refer to Specifications, “Alternator”. More than one section of the poly v-belt is displaced in one rib of a maximum length of 50.8 mm (2 inch). To replace the poly v-belt, refer to Disassembly and Assembly, “Alternator Belt - Remove and Install”. If necessary, replace the belt tensioner.
Refer to Disassembly and Assembly, “Alternator Belt - Remove and Install” for the correct procedure. i03918602 V-Belt - Test i03923009 Electric Starting System - Test The engine is equipped with an automatic belt tensioner. Manual adjustment of the belt is not required. General Information Poly V-Belt Power which is available during cranking varies according to the temperature and condition of the batteries. Table 17 shows the voltages which are expected from a battery at the various temperature ranges. NOTICE Ensure that the engine is stopped before any servic- ing or repair is performed. Table 17 Table 18 shows the maximum acceptable loss of voltage in the battery circuit.
The battery circuit supplies high current to the starting motor. The values in the table are for engines which have service of 2000 hours or more. The voltage drop for new machines is less than the voltage shown in table 18 . Table 18 Illustration 118 g02151161 Typical example To maximize the engine performance, inspect the poly v-belt (1) for wear and for cracking. Replace the poly v-belt if the belt is worn or damaged. Check the poly v-belt (1) for cracks, splits, glazing, grease, displacement of the cord and evidence of fluid contamination. The poly v-belt must be replaced if the following conditions are present. The poly v-belt (1) has a crack in more than one rib.
Voltage drops that are greater than the amounts in table 18 are caused most often by the following conditions:
Typical Voltage Of Electrical System During Cranking At Vari- ous Ambient Temperatures Temperature 12 V System 24 V System −23 to −7°C (−10 to 20°F) 6 to 8 V 12 to 16 V −7 to 10°C (20 to 50°F) 7 to 9 V 14 to 18 V 10 to 27°C (50 to 80°F) 8 to 10 V 16 to 24 V Maximum Acceptable Voltage Drop In The Starting Motor Cir- cuit During Cranking Circuit 12 V System 24 V System Battery post “-” to the starting motor terminal “-” 0.7 V 1.4 V Drop across the discon- nect switch 0.5 V 1.0 V Battery post “+” to the ter- minal of the starting mo- tor solenoid “+” 8 to 10 V 16 to 20 V Solenoid terminal “Bat” to the solenoid terminal “Mtr” 0.4 V 0.8 V