Engine Operation 36 UENR4490-01 Coolant Flow Illustration 30 g02332698 Typical example (1) Radiator (2) Water temperature regulator and housing (3) Bypass for the water temperature regulator (4) Exhaust gas cooler (NRS) (5) Cylinder head (6) Cylinder block (7) Engine oil cooler (8) Water pump The coolant flows from the bottom of the radiator (1) to the centrifugal water pump (8). The water pump (8) is installed on the front of the timing case. The water pump (8) is driven by a gear. The gear of the fuel injection pump drives the water pump gear. Some coolant flows through a cavity in the front of the cylinder head (5).

Some coolant is diverted into the exhaust gas cooler (4) by a coolant pipe in the rear of the cylinder head (5). The coolant then flows out of the exhaust gas cooler (4) to the cavity in the cylinder head (5). The water pump (8) contains a rotary seal that uses the engine coolant as a lubricating medium. This will ensure that an adequate sealing film is created. The sealing film is maintained in order to reduce heat generation. Heat that is generated by the rotating sealing faces under normal operating conditions causes a small flow of coolant to be emitted into a chamber. The water pump (8) pumps the coolant through a passage in the timing case to the front of the cylinder block (6).

The coolant enters a passage in the left side of the cylinder block (6). Some coolant enters the cylinder block. Some coolant passes over the element of the oil cooler (7). The coolant then enters the block (6). Coolant flows around the outside of the cylinders then flows from the cylinder block into the cylinder head (5).