Perkins — Perkins 1204F-E44TA and 1204F-E44TTA Industrial Engine Systems Operation Manual

UENR4490-01 35 Engine Operation Even though the system has been purged of DEF there are small quantities of DEF that can be left behind. The DEF supply line, suction, and the back flow line are heated to thaw any remaining DEF in the lines. The heated lines will prevent restrictions in the pump and injector once the system begins to dose. Water pump Cylinder block Oil cooler Exhaust gas cooler (NRS) The heated lines have the following characteristics.

Cylinder head Thermoplastic core tube with fabric reinforcement Water temperature regulator Stainless steel heating wire Extruded thermoplastic jacket Heat/abrasion shield Quick disconnect connector Cold-Weather Operation Since DEF freezes at −11.5° C (11.3° F), the system can thaw the DEF before dosing. Engine coolant is supplied to the PETU. The coolant diverter valve will turn on anytime the DEF Tank temperature is less the 15° C (59° F) at start-up. During operation, if the DEF tank temperature drops below 20° C (68° F) or ambient temperature falls below 0° C (32° F) then the coolant diverter valve will activate to keep the DEF from freezing.

The tubes running through the tank will thaw the DEF to a useable temperature. Then DEF dosing will occur once the DEF has been thawed and the DEF tank temperature is greater than −8° C (18° F). The DEF dosing will not wait for the entire tank to thawed. The DEF pump is heated by an internal heating element. The coolant will then return to the engine water pump inlet. The DEF supply lines, suction lines, and backflow lines are heated electrically. The DEF dosing system must be fully functional within 70 minutes following initial start-up. Note: If the DEF has not been removed from the lines and pump during cold-weather operation, the DEF will expand as the fluid freezes and damage the pump.

For this reason the purge process must be followed in cold weather. Refer to Operation and Maintenance Manual, “Battery Disconnect Switch” for more information. Do NOT turn off battery power until this pump has completed the purge cycle. i04135351 Cooling System Introduction The cooling system has the following components: Radiator