Air Inlet and Exhaust System 94 UENR4490-01 Illustration 81 g03706092 Typical example Illustration 82 g02424917 Typical example 1. Disconnect the pipe for the boost sensor (3) at the wastegate actuator (1). Connect an air supply to the wastegate actuator that can be adjusted accurately. 1. Follow steps 1.a to 1.i in order to test the coolant side of the exhaust gas cooler (NRS). a. Plug the coolant inlet (2) of the exhaust gas cooler (NRS) (3). 2. Install Tooling (A) to the turbocharger so that the end of the actuator rod (2) is in contact with Tooling (A). This will measure axial movement of the actuator rod (2). b. Plug the coolant outlet port (4) with tube and pressure regulator assembly.

3. Slowly apply air pressure to the wastegate so that the actuator rod (2) moves 1.0 mm (0.039 inch). Refer to Specifications, “Turbocharger” for the correct pressure for the wastegate. Ensure that the dial indicator returns to zero when the air pressure is released. Repeat the test several times. This will ensure that an accurate reading is obtained. c. Make sure that the air pressure regulator is closed and connect compressed air to the pressure regulator. d. Use a suitable pressure gauge in order to apply an air pressure of 250 kPa (36 psi) to the exhaust gas cooler (NRS). e.

While the exhaust gas cooler (NRS) is still pressurized, submerge the cooler in water that is at ambient temperature. 4. If the operation of the wastegate is not correct, the turbocharger will need to be replaced. f. Allow the exhaust gas cooler (NRS) to settle in order for the air that is trapped to escape. 5. Repeat steps 2 to 3 in order to repeat the pressure test. 6. If the air pressure is correct, remove the air supply. Remove Tooling (A). Install the pipe for the boost sensor (3). g. Observe the exhaust gas cooler (NRS) for air bubbles that indicate a leak. If air bubbles are seen within 3 minutes, this indicates a leak with the exhaust gas cooler (NRS).

Note the location or the origin of the leak. Record this information. i04249329 Exhaust Cooler (NRS) - Test h. If no bubbles are detected after 3 minutes, the exhaust gas cooler (NRS) is reusable. Air Under Water Leak Test Procedure . i. Remove the exhaust gas cooler (NRS) from the water. If the exhaust gas cooler (NRS) does not leak, the problem may be elsewhere in the