Komatsu — 24.1.7 CLEAN, CHECK RADIATOR FINS

24. SERVICE PROCEDURE 24.1.7 CLEAN, CHECK RADIATOR FINS A WARNING If compressed air, steam, or water hit your body directly, there is danger of injury. Always wear protective glasses, mask, and safety shoes. If the radiator fins are clogged or dirty, clean and inspect them. 1. Remove bolts @ (4 bolts). 2. Open the A side (hinge side) of the radiator mask. It opens approx. 10 mm. 3. Leave the B side of the radiator mask open. 4. Clean the radiator fins clogged with mud, dust and leaves with compressed air. Steam or water may be used instead of compressed air. REMARK Check the rubber hose. If the hose is found to have cracks to be hardened by ageing, replace such hose with new one.

Further, loosen hose clamp should also be checked. 5. When closing the radiator mask, always push in the A side first, then push in the B side, align the bolt holes, and tighten bolt 0. 3-34