Komatsu — 24.6.8 CHECK FOR LOOSE ROPS MOUNT BOLTS

24. SERVICE PROCEDURE 24.6.5 REPLACE CORROSION RESISTOR I/cJ--=w~-~, \ CARTRIDGE (D65P, D65EX, PX ONLY) 1. Screw in valve 0 at the top of the corrosion resistor. 2. Using a filter wrench, turn cartridge 0 to the left, and remove it. 3. L .__ Coat the seal surface of the new cartridge with engine oil, then install it to the filter holder. 4. When installing, bring the packing surface into contact with the seal surface of the filter holder, then tighten approx. 2/3 turns. 5. Open valve 0. Always use a genuine Komatsu cartridge. 24.6.6 CHECK ALL TIGHTENING TURBOCHARGER (D65P, D65EX, PX ONLY) PARTS OF Contact your Komatsu distributor to have the tightening portions checked.

24.6.7 CHECK PLAY OF TURBOCHARGER ROTOR (D65P, D65EX, PX ONLY) Contact your Komatsu distributor to have the play checked. 24.6.8 CHECK FOR LOOSE ROPS MOUNT BOLTS Check for loose and damaged bolts. If any loose bolt is found, tighten to a torque of 94.5 k 10.5 kgm. If any damaged bolt is found, replace the bolt with a genuine Komatsu bolt. 3-68