Operating & maintenance manual 21 Maintenance certificate C: At intervals of 500 operating hours 21.1.1 Replacing the filter cartridges of the preliminary fuel filter 50 operating hours after the initial operation or subsequently, at intervals of 500 operating hours, you need to check the preliminary fuel filter. At intervals of 500 operating hours (or every 12 months, whichever applies first), replace the filter cartridges of the preliminary fuel filter ( 2 ). Put a receptacle under the fuel filter in order to collect any leaking fuel. Unscrew both filter housings (cartridges) and dispose of them in accordance with waste disposal key 150299 (EU).
Use clean oil to slightly lubricate the sealing surfaces of the new filter cartridges. Attach the filter cartridges and screw them on manually. Let the Diesel engine turn by actuating the starter. Open the fuel ventilation screw and ventilate the fuel system (see Deutz service manual for instructions). 2 Fig. 105 Preliminary fuel filter 21.1.2 Engine oil change 50 operating hours after the initial operation; subsequently, at intervals of 500 operating hours: Start the Diesel engine and wait until it has reached operating temperature. Stop the Diesel engine and pull out the ignition key. Place a sufficiently dimensioned receptacle under the drain plug ( 3 ) of the Diesel engine.
Unscrew the oil drain plug ( 3 ), pull out the oil dipstick ( 1 ) and drain the oil. Dispose of the waste oil in an environmentally friendly way, according to the applicable regulations. EU waste disposal key: 130202 (EU). Screw in the oil drain plug ( 3 ) with a new o-ring. Replacing the oil fiter: Place a receptacle under the oil filter ( 2 ) to collect any leaking oil. Unscrew the filter cartridge and dispose of it in an environmentally friendly way, according to the applicable regulations. EU waste disposal key:150299 (EU). Use clean oil to lubricate the surface of the filter sealing. Attach the filter cartridge and screw it on manually. 1 3 2 Fig. 106 Engine oil change 90