Operating & maintenance manual 21.2 Maintenance work referring to the hydraulic system 21.2.1 Replacing the hydraulic oil and the oil filter cartridge Replace the oil filter cartridge for the hydraulic oil 50 hours after the initial operation and subsequently, at intervals of 500 operating hours: Slightly loosen the filter cartridge ( 3 ) by means of a tension band or a similar tool, but do not screw it off yet. In order to prevent the contents of the suction pipe from leaking, stop loosening the filter cartridge as soon as a suction sound is audible. The air intake causes the oil in the suction pipe to flow back into the tank.
As soon as the suction sound stops, unscrew the oil filter cartridge and remove it in an environmentally friendly way. EU waste disposal key: 150299 (EU ). Use clean oil to lubricate the sealing of the filter head ( 4 ). Lubricate the new oil filter cartridge ( 3 ) with clean hydraulic oil. Attach the new oil filter cartridge and screw it on manually. Fig. 109 Replacing the oil filter cartridge Unscrew the filler neck with the oil dipstick ( 1 ) and check the oil level. If necessary, add hydraulic oil. Clean the ventilation head ( 2 ). In case hydraulic oil needs to be added, observe the required specifications in the Table of lubricants . Fig.
110 Hydraulic oil level 92 SAFETY Before carrying out any maintenance work related to the hydraulic system, refer to the table of lubricants for information on the required type of hydraulic oil. INSTRUCTIONS NOTICE Prior to replacing the filter cartridge (3), place an oilpan under the hydraulic pump. NOTICE Do not use a tension band to tighten the filter cartridge! To prevent the content of the suction hose from pouring out, loosen the oil filter cartridge only until a suction sound is audible. The entering air causes the oil in the hose to flow back into the tank.