OPERATIONAL PERFORMANCE TEST / Component Test Adjustment of Max. Flow Rate and Min. Flow Rate The flow rate is adjusted by changing the servo piston max. stroke. Adjustment of max flow rate. Loosen nut (2) on the large chamber side end of the servo piston and turn adjusting screw (1). Adjustment of min. flow rate. Loosen nut (3) on the small chamber side end of the servo piston and turn adjusting screw (4). NOTE: Illustration shows the main pump. 1 2 3 4 NOTE: Change in Flow Rate (Reference) Main Pump 1 Speed: 1803 min -1 Main Pump 2 Speed: 1750 min -1 Fan Pump Seed: 1750 min -1 T1J1-04-05-007 Adjustment of Max.
Flow Rate Q W107-02-05-129 4 I Flow Rate Increase Flow Rate Decrease W107-02-05-129 I NOTE: I: The signal current of pump control sole- noid valve. T4-5-18 Adjusting Screw Turn 1/4 6.9 L/min 6.7 L/min 2.8 L/min Flow Rate Change (Main Pump 1) Flow Rate Change (Main Pump 2) Flow Rate Change (Fan Pump) 1 Flow Rate Flow Rate Decrease Increase Adjustment of Min. Flow Rate Q