OPERATIONAL PERFORMANCE TEST / Standard Performance Test Reference Page OVERLOAD RELIEF VALVE SET PRESSURE MPa (kgf/cm 2 ) T4-5-12 Backhoe Boom, Arm, Bucket, and Auxiliary Close Auxiliary Open Boom (Lower) (When operating boom mode selector) MAIN PUMP FLOW RATE MEASUREMENT L/min T4-5-14 FAN PUMP FLOW RATE MEASUREMENT L/min T4-5-16 SWING MOTOR DRAINAGE With constant maximum speed L/min T4-5-22 TRAVEL MOTOR DRAINAGE With the track jacked up L/min T4-5-24 T4-2-4 Performance Standard Remarks 35.3+1.0 0 (360+10 ) 0 27.9+1.0 0 (280+10 ) 0 12.0+1.0 0 (120+10 ) 0 − Refer to page T4-2-5 − Refer to page T4-2-6 0.2 to 0.3 5 or less Allowable limit: 10