Hitachi Construction Machinery — Main Pump P-Q Diagram

OPERATIONAL PERFORMANCE TEST / Standard MAIN PUMP P-Q DIAGRAM Hydraulic P-Q Control (REFERENCE: Measured at Test Stand) Rated Pump Speed: 1750 min -1 (rpm) Power Mode Switch: P Mode Hydraulic Oil Temperature: 50 ± 5°C Delivery Pressure MPa (kgf/cm 2 , psi) Flow Rate L/min (US gpm) A 20 (205, 2908) Approx. 250 (66) B 25 (255, 3635) Approx. 190 (50) NOTE: Refer to T4-5-14. C 30 (305, 4361) Approx. 160 (42) L/min 400 350 300 Flow Rate 250 200 150 100 50 0 T1J1-04-02-001 0 Delivery Pressure T4-2-5 A B C 5.0 10.0 15.0 20.0 25.0 30.0 35.0 (51) (102) (153) (204) (255) (306) (357) MPa (kgf/cm2)