TESTING AND ADJUSTING MEASURING OUTPUT PRESSURE OF PPC VALVE ADJUSTING STRAIGHT TILTDOZER D65E-12 D60, 65P-12 D65EX, PX-12 fl Adjust as follows when installing after the blade has been removed or disassembled. 1. Adjusting amount of blade tilt 1) After installing the blade, adjust with handle (1) so that dimension A is as follows. Dimention A : 1,150 mm 2) Adjust the amount of tilt on the left and right sides as follows. Amount of tilt Unit: mm 014012 3) If the amount of tilt is not the same on the left and right, adjust as follows with handle (1) to make the tilt ununiform on the left and right sides. • If B2 > B1 : Adjust slightly so that dimen- sion A becomes shorter • If B2 B1 :
Adjust slightly so that di- mension A becomes longer 20-122-1 5 Tilt position Model Right tilt B1 left tilt B2 D60, 65P-12 D65PX-12 455 455 D65E-12 D65EX-12 440 440