hitachi — Fault Code List MC

TROUBLESHOOTING / Troubleshooting A T5-5-14 Fault Code Trouble Cause Influenced Control 11404-2 Abnormal Current Feedback of So- lenoid Valve Unit (SG) (Relief Pressure Control) Current: Both of Higher than 920 mA or Less than 60 mA • Power Digging Control • Auto-Power Lift Control • Travel Pressure Increasing Con- trol 11404-3 Abnormal Feedback High Current of Solenoid Valve Unit (SG) (Relief Pressure Control) Current: Higher than 920 mA • Power Digging Control • Auto-Power Lift Control • Travel Pressure Increasing Con- trol 11404-4 Abnormal Feedback Low Current of Solenoid Valve Unit (SG) (Relief Pressure Control) Current:

Less than 56 mA • Power Digging Control • Auto-Power Lift Control • Travel Pressure Increasing Con- trol 11405-2 Abnormal Current Feedback of So- lenoid Valve Unit (SI) (Travel Motor Fast Speed Selection) Current: Both of Higher than 920 mA or Less than 60 mA Travel Motor Swash Angle Selection Control 11405-3 Abnormal Feedback High Current of Solenoid Valve Unit (SI) (Travel Mo- tor Fast Speed Selection) Current: Higher than 920 mA Travel Motor Swash Angle Selection Control 11405-4 Abnormal Feedback Low Current of Solenoid Valve Unit (SI) (Travel Mo- tor Fast Speed Selection) Current:

Less than 56 mA Travel Motor Swash Angle Selection Control 11410-2 (ZX160-3 Class Only) Abnormal Current Feedback of Maximum Pump 1 Flow Rate Limit Control Solenoid Valve Current: Both of Higher than 920 mA or Less than 60 mA • Pump 1 Flow Rate Limit Control • Pump 1 Flow Rate Control Valve at Travel 11410-3 (ZX160-3 Class Only) Abnormal Feedback High Current of Maximum Pump 1 Flow Rate Limit Control Solenoid Valve Current: Higher than 920 mA • Pump 1 Flow Rate Limit Control • Pump 1 Flow Rate Control Valve at Travel 11410-4 (ZX160-3 Class Only) Abnormal Feedback Low Current of Maximum Pump 1 Flow Rate Limit Control Solenoid Valve Current:

Less than 56 mA • Pump 1 Flow Rate Limit Control • Pump 1 Flow Rate Control Valve at Travel