TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11206 Disconnect connector MC-D of MC. Check for continuity in harnes between terminal #D11 of harness end of connector MC-D in MC and terminal #2 in pump 1 control pressure sensor. YES Faulty harness between MC and pump 1 control pressure sensor. YES To A Check if voltage between terminal #1 of harness end of connector in pump 1 control pressure sensor and machine is specification. Switch pump 1 control pressure sensor with pump 2 control pressure sensor and retry. Check if fault code is switched. · Key switch: ON NO Open circuit in harness between MC and pump 1 control pressure sensor (terminal #1). · Key switch: ON · Specification:
More than 0.25 V, Less than 4.75 V NO YES Faulty pump 1 control pressure sensor. Check if voltage be- tween terminal #D11 of harness end of connector MC-D and machine is 0 V. YES Faulty MC. A Shorted circuit in harness between MC and pump 1 control pressure sensor. · Key switch: ON NO Connector (Harness end of connector viewed from the open side) MC Connector MC-D Pump 1 Control Pressure Sensor #D11 T183-05-04-009 T5-5-77 Fault Code Trouble Cause Influenced Control 11206-3 Abnoraml Pump 1 Control Pressure Sensor High Voltage Voltage: 4.75 V or higher • E Mode Control • Travel Motor Swash Angle Se- lection Control 11206-4 Abnormal Pump 1 Control Pressure Sensor Low Voltage Voltage:
Less than 0.25 V • E Mode Control • Travel Motor Swash Angle Se- lection Control Disconnect connector of pump 1 control pressure sensor. Check if voltage between NO terminals #1 and #3 of harness end of connector is 5±0.5 V. NO Open circuit in harness between MC and pump 1 control pressure sensor (terminal #3). 1 2 3