TROUBLESHOOTING / Troubleshooting A PILOT FAILURE MC FAULT CODE 11301 Disconnect connector MC-C of MC. Check for continuity in harnes between terminal #C13 of harness end of connector MC-C in MC and terminal #2 in swing pilot pressure sensor. YES Open circuit in harness between MC and swing pilot pressure sensor. YES NO To A Open circuit in harness between MC and swing pilot pressure sensor (terminal #3). Switch swing pilot pressure sensor with other pressure sensor and retry. Check if fault code disappears. Check if voltage between terminal #1 of harness end of connector in pressure sensor and machine is specification. YES · Key switch: ON NO · Key switch: ON · Specification:
More than 0.25 V, Less than 4.75 V Open circuit in harness between MC and swing pilot pressure sensor (terminal #1). NO Faulty swing pilot pressure sensor. YES Check if voltage be- tween terminal #C13 of harness end of connector MC-C and machine is 0 V. A Shorted circuit in harness between MC and swing pilot pres- sure sensor. Connector (Harness end of connector viewed from the open side) · Key switch: ON NO MC Connector MC-C Pilot Pressure Sensor (Swing) C23 C31 T5-5-79 Fault Code Trouble Cause Influenced Control 11301-3 Abnormal Swing Pilot Pres- sure Sensor High Voltage Voltage:
4.75 V or higher • Arm Regenerative Control • Attachment Flow Rate Control • Swing Alarm Control 11301-4 Abnormal Swing Pilot Pres- sure Sensor Low Voltage Voltage: Less than 0.25 V • Arm Regenerative Control • Attachment Flow Rate Control • Swing Alarm Control Disconnect connector of swing pilot pressure sensor. Check if voltage NO between terminals #1 and #3 of harness end of connector is 5±0.5 V. ES Faulty MC. #C13 C1 C1 1 2 3