TROUBLESHOOTING / Troubleshooting A · Key switch: ON · Key switch: OFF Connector ICF Connector ICF-C (Harness end) Monitor Unit Connector Monitor-B (Harness end) #C5 #C11 T1V1-05-04-002 T183-05-04-013 T5-5-96 Connect connector in MC. A Check if fault code 11004-2 is displayed. Connect connector in MC. Check if fault code NO Check the connections of MC and connector. 11004-2 is displayed. Faulty MC. YES NO Check the connections of Connect connector ECM and connector. in ECM. YES Check if fault code 11004-2 is displayed. Faulty ECM. YES · Key switch: ON Connect connector NO Check the connection of B in ICF. ICF and connector. YES Check if fault code 11004-2 is Connect connector in displayed.
Faulty ICF. ECM. YES Disconnect · Key switch: ON connector ICF-C in ICF. Check the connections of NO Check if resistance Connect connector monitor unit and NO between terminals in the monitor unit. connector. YES #C5 and #C11 of Check if fault code harness end of Connect connector in 11004-2 is connector is within ICF. displayed. Faulty monitor unit. 60±10 Ω. Disconnect YES connector · Key switch: ON · Key switch: OFF NO monitor-B in the monitor unit. Check if resistance Failure in any controller in between terminals MC, ICF, ECM or #B6 and #B7 of NO monitor unit. harness end of connector is within 120±10 Ω. NO Check the connections of ECM and connector. Connect connector in ECM.
Check if fault code YES 11004-2 is displayed. Connect connector in ICF. Check if fault code YES 11004-2 is displayed. Connect connector in ECM. Disconnect connector ICF-C in ICF. Check if resistance NO between terminals #C5 and #C11 of harness end of connector is within 60±10 Ω. Connect connector in the monitor unit. YES Check if fault code 11004-2 is displayed. Connect connector in ICF. Disconnect connector NO monitor-B in the monitor unit. Check if resistance between terminals #B6 and #B7 of harness end of connector is within 120±10 Ω. Faulty monitor unit. YES #B7 #B6