TROUBLESHOOTING / Troubleshooting A CAN HARNESS CHECK (MC FAULT CODE 11911, 11918) Check the wiring connections first. T5-5-98 Disconnect all Open circuit in CAN connectors of MC, ICF, YES harness between ground ECM and monitor unit. circuit and CAN circuit. YES Check for continuity between ground circuit (MC, ICF, ECM, Check for continuity monitor unit) and CAN between power circuit. circuit (MC, ICF, Check for continuity in NO ECM, monitor unit) · Key switch: OFF YES CAN harness between and CAN circuit. · Refer to MC and monitor unit. “Discontinuity Check · Key switch: OFF · Key switch: OFF between CAN Circuit · Refer to · Refer to “Continuity and Ground Circuit”.
“Discontinuity Check between CAN Circuit Check in CAN and Power Circuit”. Harness”. Retry by using Dr. ZX. Check if fault code Open circuit in CAN 11004-2 is displayed. harness between MC and NO monitor unit. Normal. NO Normal. NO Check for continuity between power circuit (MC, ICF, NO ECM, monitor unit) and CAN circuit. Check for continuity in CAN harness between YES MC and monitor unit.