TROUBLESHOOTING / Troubleshooting A Shorted circuit in CAN harness between power circuit and CAN circuit. YES Shorted circuit in CAN harness between key signal circuit and CAN circuit. YES · Key switch: OFF · Refer to “Discontinuity Check between CAN Circuit and Key Signal Circuit”. YES Shorted circuit in CAN harness. YES To A · Key switch: OFF · Refer to “Discontinuity Check in CAN Harness”. To B Connector · Key switch: OFF MC Connector MC-C (Harness end) · Key switch: OFF #C15 #C4 C23 C31 Monitor Unit Connector Monitor-B (Harness end) #B7 #B6 T183-05-04-013 T5-5-99 Check for continuity etween key signal ircuit (MC, ICF, NO ECM, monitor unit) nd CAN circuit.
Check for continuity between High side and Low side in CAN NO harness. Connect all connectors except connector MC-C in MC. Check if resistance NO between terminals #C4 and #C15 of harness end of connector MC-C is within 60±10 Ω. Connect connector in MC. Disconnect connector monitor-B in the monitor unit. NO Check if resistance between terminals #B6 and #B7 of harness end of connector is within 120±10 Ω. C1 C10