hitachi — Other Failures MC Fault Code 11901

TROUBLESHOOTING / Troubleshooting A OTHER FAILURES MC FAULT CODE 11901 Specification of Hydraulic Oil Temperature Sensor Connector (Harness end of connector viewed from the open side) MC Connector MC-D #D2 T183-05-04-009 #D6 Hydraulic Oil Temperature Sensor T5-5-101 Fault Code Trouble Cause Influenced Control 11901-3 Hydraulic Oil Temperature Sensor High Voltage Voltage: 4.52 V or higher • Auto-Warming Up Control • Arm Regenerative Control • Digging Regenerative Control 11901-4 Hydraulic Oil Temperature Sensor Low Voltage Voltage: Less than 0.23 V • Auto-Warming Up Control • Arm Regenerative Control • Digging Regenerative Control Connect terminals #1 YES Faulty MC.

and #2 of harness end of connector in hydraulic oil temperature sensor by YES using a clip. Connect terminal #D6 Open circuit in harness of harness end of YES between MC and Disconnect connector connector MC-D in hydraulic oil temperature MC-D from MC. MC to machine. sensor (terminal #1). Check for continuity Disconnect connector of Check for continuity between terminals #D2 hydraulic oil temperature NO between terminals #2 and #D6 of harness sensor. of harness end of Open circuit in harness end of connector Check if resistance at connector in hydraulic between MC and MC-D. NO sensor end connector is oil temperature hydraulic oil temperature specification. sensor and machine.

sensor (terminal #2). Specification: Re Faulty hydraulic oil NO temperature sensor. Faulty hydraulic oil temperature sensor. NO Connect terminals #1 and #2 of harness end of connector in hydraulic oil temperature sensor by using a clip. YES Disconnect connector MC-D from MC. Check for continuity between terminals #D2 and #D6 of harness end of connector MC-D. Hydraulic Oil Temperature (°C) Resistance (kΩ) -20 16.2±1.6 0 (5.88) 20 2.45±0.24 40 (1.14) 60 (0.534) 80 0.322 1 2