TROUBLESHOOTING / Troubleshooting B E-2 Even if starter rotates, engine does not start. Related MC Fault Code: None Check the wiring connections first. Connect terminal #1 of harness end of connector in ECM main relay to ma- chine. Check for continuity between terminals #21, #40 of harness end of connector in ECM and machine. Disconnect ECM main relay from connector. Check if voltage be- tween terminal #3 of harness end of con- nector and machine is specification. YES Switch ECM main relay with other gen- eral relay. Check if engine starts. Connect terminal #5 of harness end of connec- tor in ECM main relay to machine. Disconnect connector in ECM.
Check for continuity between terminals #2, #5 of harness end of connector and machine. YES Open circuit in harness between ECM main relay and ECM. NO NO · Specification: 24V NO Connector (Harness end of connector viewed from the open side) ECM Main Relay ECM Connector #21 #24 #5 T183-05-04-003 T1GR-05-04-002 #40 #2 T5-6-60 YES Faulty ECM main relay. Open circuit in harness between key switch and ECM main relay. · Check if fuse #8 is blown.