TROUBLESHOOTING / Troubleshooting B Disconnect con- nector ICF-C in ICF. Check if voltage between terminal #C7 of harness end of connector and machine is speci- fication. YES Open circuit in harness between key switch and monitor unit. Disconnect connector MC-B in MC. Check if voltage between terminal #B16 of harness end of connector and machine is specification. Open circuit in harness between key switch and MC. YES Check if fuse #18 is blown. Open circuit in harness between key switch and ICF. YES · Key switch: ON · Specification: 24 V Check if fuse #18 is blown. Check if voltage between terminal #24 of harness end of connector in ECM and ma- chine is specifica- tion.
Check for conti- nuity between terminal #2 of harness end of connector in ECM main relay and machine. YES · Key switch: ON · Specification: 24 V NO Check if fuse #18 is blown. YES Open circuit in harness between key switch and ECM. · Key switch: ON · Specification: 24 V NO Check if fuse #18 is blown. Faulty ground in ECM main relay. NO Open circuit in harness between ECM main relay and ECM. NO Connector MC-B Connector ICF-C #B16 B1 B8 T1V1-05-04-002 B25 B19 #C7 T5-6-61 NO I