TROUBLESHOOTING / Troubleshooting B · Check if fuse #16 is blown. T5-6-85 ∞ Ω Faulty glow plug. Faulty glow relay, or NO faulty harness between Connect connector in glow relay and glow plug. glow relay. Connect ter- YES minal #4 of harness end of connector to machine. Check if voltage at glow plug is 20 to 24 V. Open circuit in harness · Key switch: ON between glow relay and YES ECM. Disconnect connector in glow relay. Check if voltages at termi- Below 10 Ω nals #1 and #3 of harness end of connector in glow relay are 20 to 24 V. · Key switch: ON If terminal #1 is 0 V, open circuit in harness be- tween glow relay and battery.
If terminal #3 is 0 NO V, open circuit in harness between glow relay and terminal M in key switch. ∞ Ω Faulty glow plug. If terminal #1 is 0 V, open circuit in harness be- tween glow relay and battery. If terminal #3 is 0 V, open circuit in harness between glow relay and terminal M in key switch.