TROUBLESHOOTING / Troubleshooting B ALL ACTUATOR SYSTEM TROUBLE- SHOOTING A-1 All actuator speeds are slow. Related MC Fault Code: 11004-2, 11100-2, 11910-2, 11401-2, 11401-3, 11401-4 Reduction in pump 1 and 2 flow rate due to some reasons or faulty pilot system (A-2) may cause this trouble. Check fuse of the torque control solenoid valve. Even if speed is satisfactory, in case power is weak, refer to the troubleshooting for faulty main relief valve (F-1). Check the wiring connections first. T5-6-86 Faulty torque control so- YES lenoid valve, or open cir- cuit in harness between MC and torque control solenoid valve. Check if fault code YES 11401-2, 11401-3 or 11401-4 is displayed.
YES Faulty CAN between MC and ECM, or faulty MC. Check if fault code 11004-2, 11100-2 or NO 11910-2 is displayed. Check if primary pilot Faulty pump device. pressure is normal. NO Fully boom raised or fully arm rolled-in Monitor item: Boom raise pilot pressure, Arm roll-in pilot pressure YES Faulty pilot pump, or clogged pilot filter. Adjust, disassemble and clean pilot relief valve. NO Check if same symp- tom appears. End. NO Faulty torque control so- lenoid valve, or open cir- cuit in harness between MC and torque control solenoid valve. End. NO Check if fault code 11401-2, 11401-3 or YES 11401-4 is displayed. YES Faulty CAN between MC and ECM, or faulty MC.