hitachi — Front Attachment System Troubleshooting

TROUBLESHOOTING / Troubleshooting B F-5 Arm roll-in speed is slow when digging. Related MC Fault Codes: 11200-3, 11200-4, 11202-3, 11202-4, 11301-3, 11301-4, 11302-3, 11302-4, 11402-2, 11402-3, 11402-4 Refer to the pages for the SYSTEM / Control System group / Digging Regenerative Control in the T/M (Operational Principle). Check if fault code is displayed. · Fault code 11200-3, 11200-4: Pump 1 delivery pressure sensor 11202-3, 11202-4: Pump 2 delivery pressure sensor 11303-3, 11303-4: Pressure sensor (arm roll-in) 11302-3, 11302-4: Pressure sensor (boom raise) 11402-2, 11402-3, 11402-4:

Solenoid valve unit (SF) YES Check if digging re- generative valve at 5-spool side in control valve is scored or bound. Faulty digging regenera- tive valve. NO Find out cause of trouble by tracing other trouble symptoms. NO T5-6-106 YES Faulty corresponding sensor, or faulty MC. Open circuit in harness between MC and sensor Faulty solenoid valve unit (SF), or open circuit in harness between sole- noid valve unit (SF) and MC YES