hitachi — Front Attachment System Troubleshooting

TROUBLESHOOTING / Troubleshooting B F-6 Bucket is slightly slow during bucket roll-in single operation. Bucket does not move smoothly during bucket roll-in single opera- tion. Related MC Fault Code: None Bucket flow rate control valve or bucket regenera- tive valve may be faulty. Refer to the COMPONENT OPERATION / Control Valve group in the T/M (Operational Principle). YES Faulty bucket regenera- tive valve. (Disassemble and clean or replace.) YES Check if bucket re- generative valve in bucket spool is bound or scored. Install a pressure gauge to hose SK connecting signal con- trol valve to bucket flow rate control valve in control valve.

When relieving during 3-combined operation of boom raise, arm roll-in and bucket roll-in, check if pres- sure is 3.9 MPa (40 kgfcm 2 ). Find out cause of trouble by tracing other trouble symptoms. NO NO Bound bucket flow rate control valve control spool in signal control valve. Check if bucket flow rate control valve in control valve is bound or scored. NO Faulty bucket flow rate control valve. (Disassem- ble and clean or replace.) YES Signal Control Valve (Control Valve Side) Bucket Flow Rate Control Valve Hose SK T1V1-05-04-005 T178-03-06-015 T5-6-107