TROUBLESHOOTING / Troubleshooting B F-7 When starting to move during combined op- eration, arm does not smoothly move. Arm starts to move slightly slow during arm roll-in single operation. These troubles often occur when temperature is low. Related MC Fault Code: None Refer to the COMPONENT OPERATION / Control Valve group in the T/M (Operational Principle). F-8 When starting to move during combined op- eration, boom does not move smoothly. Boom starts to move slightly slow during boom lower single operation. Related MC Fault Code: None Refer to the COMPONENT OPERATION / Control Valve group in the T/M (Operational Principle). YES Faulty arm regenerative valve.
(Disassemble and clean or replace.) NO Check if arm regenera- tive valve is bound or scored. Find out cause of trouble by tracing other trouble symptoms. Check if arm anti-drift valve is bound or scored. NO Faulty arm anti-drift valve. (Disassemble and clean or replace.) YES Faulty boom lower me- ter-in cut valve. (Disas- semble, clean or replace.) NO NO Check if boom lower meter-in cut valve is bound or scored. NO Find out cause of trouble by tracing other trouble symptoms. Check if boom re- generative valve is bound or scored. Check if boom anti-drift valve is bound or scored. YES Faulty boom anti-drift valve. (Disassemble and clean or replace.) YES T5-6-108 Faulty boom regenerative valve.
(Disassemble and clean or replace.) YES