hitachi — Front Attachment System Troubleshooting

TROUBLESHOOTING / Troubleshooting B F-14 Attachment speed is fast during combined operation of attachment (optional) and front attachment (when breaker attached with auxiliary flow combining line is used). Related MC Fault Code: None Check the wiring connections first. Connector (Harness end of connector viewed from the open side) Shorted circuit in har- ness between MC and pressure sensor (aux- iliary). NO Disconnect connec- tor MC-D in MC. Check if voltage be- tween terminal #D5 of harness end of connector and ma- chine is 0 V. YES Switch pressure sen- sor (arm roll-out) with other pressure sen- sor. Check if fault code for switched pressure sensor is displayed.

Disconnect connector in pressure sensor (auxiliary). Check if voltage be- tween terminals #1 and #3 of harness end of connector is 5 ± 0.5 V. YES NO · Key switch: ON Switch pressure sensor (auxiliary) with other pressure sensor. Check if fault code for switched pres- sure sensor is dis- played. YES Open circuit in har- ness between MC and pressure sensor (aux- iliary) (terminal #3). · Key switch: ON Check if voltage be- tween terminals #1 of harness end of con- nector in pressure sensor (auxiliary) and machine is between 0.25 and 4.25 V. NO Open circuit in har- ness between MC and pressure sensor (aux- iliary) (terminal #1). NO · Key switch: ON Faulty pressure sen- sor (auxiliary).

YES Pilot Pressure Sensor (Auxiliary) Pilot Pressure Sensor (Arm Roll-Out) MC Connector MC-A #A7 #A23 T1V1-05-07-102 Auxiliary Flow Combining Solenoid Valve T183-05-04-008 MC Connector MC-D #D5 T1V1-05-04-003 #D9 T183-05-04-009 T5-6-116