hitachi — Front Attachment System Troubleshooting

TROUBLESHOOTING / Troubleshooting B NO Shorted circuit in harness between MC and pres- sure sensor (arm roll-out). Disconnect connector MC-D in MC. Check if voltage between ter- minals #D9 of harness end of connector and machine is 0 V. Disconnect connector MC-B in MC and con- nector in auxiliary flow combining solenoid valve. Check for continuity between terminals #1 and #2 of harness end of connector in auxil- iary flow combining solenoid valve. NO Disconnect connector in pressure sensor (arm roll-out). Check if voltage be- tween terminals #1 and #3 of harness end of connector is 5 ± 0.5 V. YES Check if auxiliary flow combining solenoid valve is bound or scored.

To A YES Shorted circuit in harness between MC and auxil- iary flow combining so- lenoid valve. YES · Key switch: ON Check if voltage be- tween terminals #1 of harness end of con- nector in pressure sensor (arm roll-out) and machine is be- tween 0.25 and 4.75 V. YES Open circuit in harness between MC and pres- sure sensor (arm roll-out) (terminal #3). NO Open circuit in harness between MC and pres- sure sensor (arm roll-out) (terminal #1). NO · Key switch: ON Faulty pressure sensor (arm roll-out). YES T5-6-117 NO C Faulty auxiliary flow YES combining solenoid valve. A Faulty auxiliary flow YES combining valve. Check if auxiliary flow combining valve in NO control valve is bound or scored.

Faulty MC. NO Faulty auxiliary flow combining solenoid valve. Faulty MC. NO Check if auxiliary flow combining valve in NO control valve is bound or scored.