TROUBLESHOOTING / Troubleshooting B SWING SYSTEM TROUBLESHOOTING S-1 Swing is slow or unmoving. Related MC Fault Code: None Check whether the pilot system is faulty or the main circuit is faulty. In case other functions (front attachment and travel) operate normally, the pilot pump is consid- ered to be normal. If the pilot system is displaying a problem, the cause of trouble may exist in the circuit after pilot valve. In case left travel speed is also slow, refer to A-3. Check if swing motor parking brake release valve is scored or bound. YES Check if parking brake release pressure is approx. 3.9 MPa (40 kgf/cm 2 ). YES · Relieve arm circuit. · Monitor item:
Front attachment con- trol pressure · Possible to display by service menu and monitoring in monitor unit. · Monitor item: Pump 2 pump control pressure · Possible to display by service menu and monitoring in monitor unit. · Specification: Refer to Operational Performance Test Sec- tion. · Monitor item: Swing control pressure · Possible to display by service menu and monitoring in monitor unit. Monitor pump control pressure. While slowly operating swing lever, check if pump control pressure varies smoothly. NO Faulty swing parking brake release spool in signal control valve. YES Monitor secondary pilot pressure. Check if secondary pilot pressure is nor- mal.
Bound pump 2 flow rate control valve in signal control valve. NO Faulty pilot valve. NO T5-6-120