hitachi — Exchange Inspection

TROUBLESHOOTING / Troubleshooting B EXCHANGE INSPECTION Exchange inspection method is a troubleshooting method to find the trouble location by exchanging the suspected part / component with another part /component having identical characteristics. Many sensors and solenoid valves used on this ma- chine are identical. Therefore, by using this switch-check method, faulty part /component, and/or harness can be easily found. Example: Abnormal pump 1 delivery pressure high voltage (MC fault code: 11200-3) Check Method: 1. Switch two delivery pressure sensors located as shown in figure A to figure B. 2. Retry troubleshooting. Result:

In case abnormal pump 2 delivery pressure high volt- age is displayed (MC fault code 11202-3), the pump 1 delivery pressure sensor is considered to be faulty. In case abnormal pump 1 delivery pressure high volt- age is displayed (MC fault code 11200-3), the pump 1 delivery pressure sensor harness is considered to be faulty. Pump 2 (5-Spool Section) Pump 1 (4-Spool Section) PP1 PP2 Figure A T157-07-04-006 T157-07-04-006 T5-6-152 Pump 2 Pump 1 (5-Spool (4-Spool Section) Section) PP1 PP2 Figure B