TROUBLESHOOTING / Electrical System Inspection ALTERNATOR CHECK In general, the alternator indicator remains off when the alternator is generating power. If the alternator indicator comes on while the engine is running, the alternator might be defective. How to check the circuit 1. Turn the key switch to the ON position. Confirm that the alternator alarm is displayed. 2. Measure voltage between teminals B and E of the alternator. If the measured voltage is around 24 V, the alternator circuit can be considered normal. If the measured voltage is low, a shortage in battery capacity or looseness of the wire connectors of alternator circuit might be cause of the malfunction.
When voltage is 0 V, the wiring between fuse box and alternator might be loose or disconnected. Also, the alternator cannot generate electricity if the ground line is disconnected. 3. Next, start the engine. Measure voltage generated while as the alternator rotates. As described above, measure voltage between terminals B and E on the alternator side. If voltage is around 28 V, the alternator is operating normally. If the rated voltage is not being generated, there is some trouble with the alternator or the regula- tor. T1V1-05-01-117 Monitor Unit Alternator Alarm B E T157-07-06-003 T5-7-7